Wednesday, February 15, 2012

After Applying PSU 102 for HFM, Smart View Error "Empty Response from Provider"



After Applying PSU 102 for HFM, Smart View Error "Empty Response from Provider" [ID 1371368.1]

 Modified 13-JAN-2012     Type PROBLEM     Status PUBLISHED 

In this Document
  Symptoms
  Changes
  Cause
  Solution

Applies to:

Hyperion Financial Management - Version: 11.1.2.1.102 to 11.1.2.1.102 - Release: 11.1 to 11.1
Information in this document applies to any platform.

Symptoms

Smart View will not connect to the HFM Office Provider.

Error  



When you enter the Smart View URL into a web browser, e.g. http://localhost/hfmofficeprovider/hfmofficeprovider.aspx (use localhost only if you are on the web server), you get a blank screen.

Changes

Installed PSU 102 for Hyperion Financial Management on a patched 11.1.2.1.0 environment.  

Cause

Certain configuration files are not replaced on install. This would only occur on a system that had previous patches installed prior to applying PSU 102.

PSU 102 was re-issued to correct this problem.

Solution

To resolve this you will need to run the EPM System Configurator and reconfigure the HFM Smart View Provider

  1. Launch the EPM Configurator on your HFM Web Server
  2. Deselect (uncheck) the "Check All" Box
  3. Expand "Financial Management"
  4. Check "Configure Web Server"
  5. Click Next
  6. Deselect everything except "Configure IIS to Enable Smart View Provider"
  7. Click Next twice.

No comments: